Compressor map
Encyclopedia
Each compressor
Gas compressor
A gas compressor is a mechanical device that increases the pressure of a gas by reducing its volume.Compressors are similar to pumps: both increase the pressure on a fluid and both can transport the fluid through a pipe. As gases are compressible, the compressor also reduces the volume of a gas...

 (or fan) in a gas turbine
Gas turbine
A gas turbine, also called a combustion turbine, is a type of internal combustion engine. It has an upstream rotating compressor coupled to a downstream turbine, and a combustion chamber in-between....

 engine has an operating map. Complete maps are either based on compressor rig test results or are predicted by a special computer program. Alternatively the map of a similar compressor can be suitably scaled.

Compressor maps are important, since they are an integral part of predicting the performance of a gas turbine engine, both at design and off-design conditions. Fans and turbine
Turbine
A turbine is a rotary engine that extracts energy from a fluid flow and converts it into useful work.The simplest turbines have one moving part, a rotor assembly, which is a shaft or drum with blades attached. Moving fluid acts on the blades, or the blades react to the flow, so that they move and...

s also have operating maps, although the latter are significantly different in appearance to that of fans and compressors.

Flow axis

The x-axis is usually some function of compressor entry mass flow, usually corrected flow
Corrected flow
Corrected Flow is the mass flow that would pass through a device if the inlet pressure and temperature corresponded to ambient conditions at Sea Level, on a Standard Day Corrected Flow is the mass flow that would pass through a device (e.g. compressor, bypass duct, etc.) if the inlet pressure and...

 or non-dimensional flow, as opposed to real flow. This axis can be considered a rough measure of the axial Mach number of the flow through the device.

Pressure ratio axis

Normally the y-axis is pressure ratio (Pexit/Pinlet), where P is stagnation (or total head) pressure.

ΔT/T (or similar), where T is stagnation (or total head) temperature, is also used.

Surge line

The slightly kinked diagonal line on the main (i.e. lower) part of the map is known as the surge (or stall) line. Above this line is a region of unstable flow, which is an area best avoided.

A compressor surge, typically, causes an abrupt reversal of the airflow through the unit, as the pumping action of the aerofoils stalls (akin to an aircraft wing stalling).

Surge margin

As the name suggests, surge margin provides a measure of how close an operating point is to surge. Unfortunately, there are a number of different definitions of surge margin. A popular one in use is defined as follows:



where:

is the mass flow at the operating point, be it steady state or transient

is the mass flow at surge, at same corrected speed as

Speed lines

The slightly curved, near vertical, lines on the main part of the map are the (constant rotational) corrected speed
Corrected speed
Corrected Speed is the speed a component would rotate at if the inlet temperature corresponded to ambient conditions at Sea Level, on a Standard Day Corrected Speed is the speed a component would rotate at if the inlet temperature corresponded to ambient conditions at Sea Level, on a Standard Day...

 lines. They are a measure of rotor blade tip Mach number.

Note on the illustration that the speed lines are not distributed linearly with flow. This is because this particular compressor is fitted with variable stators, which open progressively as speed increases, causing an exaggerated increase in flow in the medium to high speed region. At low speed, the variable stators are locked, causing a more linear relationship between speed and flow.

Also note that beyond 100% flow, the speed lines close up rapidly, due to choking. Beyond choke, any further increase in speed will generate no further increase in airflow.

Efficiency axis

A sub-plot shows the variation of isentropic (i.e. adiabatic
Adiabatic process
In thermodynamics, an adiabatic process or an isocaloric process is a thermodynamic process in which the net heat transfer to or from the working fluid is zero. Such a process can occur if the container of the system has thermally-insulated walls or the process happens in an extremely short time,...

) efficiency with flow, at constant speed. Some maps use polytropic efficiency.
Alternatively, for illustrative purposes, efficiency contours are sometimes cross-plotted onto the main map.

Note that the locus of peak efficiency exhibits a slight kink in its upward trend. This due to the choking-up of the compressor as speed increases, with the variable stators closed-off. The trend line resumes, once the variables start to move open.

Working line

Also shown on the map, is a typical steady state working (or operating/running) line. This is a locus of the operating points of the engine, as it is throttled.

Being a high pressure ratio device, the working line is relatively shallow. If the unit had no variable geometry, there would be handling problems, because the surge line would be very steep and cross the working line at part-flow..

During a slam-acceleration from, say, a mid-throttle setting, the compressor working line will move rapidly towards surge and then slowly approach the steady state operating point, further up the map. The reverse effect occurs during a slam-deceleration. These effects are caused by the sluggish response of the spool (i.e. inertia effects) to rapid changes in engine fuel flow. Compressor surge is a particular problem during slam-accelerations and can be overcome by suitable adjustments to the fuelling schedule and/or use of blow-off (bleeding air off the compressor, for handling purposes).

In the particular example shown, a slam-accel from ground idle would cause an HP compressor surge. Opening the blow-off would help, but some changes to the variable stator schedule might also be required.

Because an HP compressor 'sees' the choked flow capacity of the HP turbine, the compressor working line is hardly affected by flight conditions. The slope of the working line approximates to a constant corrected outlet flow.

Fan map

As the second illustration shows, a low pressure ratio fan (such as that used on a high bypass ratio
Bypass ratio
The term bypass ratio relates to the design of turbofan engines, commonly used in aviation. It is defined as the ratio between the mass flow rate of air drawn in by the fan bypassing the engine core to the mass flow rate passing through the engine core....

 turbofan) has a range of working lines. At high flight speeds, the ram pressure ratio factors up the cold nozzle pressure ratio, causing the nozzle to choke. Above the choking condition, the working lines tend to coalesce into a unique steep straight line. When the nozzle unchokes, the working line starts to become more curved, reflecting the curvature of the nozzle characteristic. With falling flight Mach number, the cold nozzle pressure ratio decreases. Initially this has no effect upon the position of the working line, apart from the curved (unchoked) tail, which becomes longer. Eventually, the cold nozzle will become unchoked at lower flight Mach numbers, even at full throttle. The working lines will now become curved, gradually migrating towards surge as flight Mach number decreases. The lowest surge margin working line occurs at static conditions.

Owing to the nature of the constraints involved, the fan working lines of a mixed turbofan are somewhat steeper than those of the equivalent unmixed engine.

The fan map shown is for the bypass (i.e. outer) section of the unit. The corresponding inner section map typically has longer, flatter, speed lines.

Military turbofans tend to have a much higher design fan pressure ratio than civil engines. Consequently the final (mixed) nozzle is choked at all flight speeds, over most of the throttle range. However, at low throttle settings the nozzle will unchoke, causing the lower end of the working lines to have a short curved tail, particularly at low flight speeds.

However, ultra-high bypass ratio turbofans have a very low design fan pressure ratio (e.g. 1.2, on the bypass section). Consequently, even at cruise flight speeds, the cold (or mixed final) propelling nozzle is unchoked. The fan working lines become more spread-out with flight Mach number, because they move bodily up the map, towards the top right hand corner. As a result, the static working line can be well into surge.

One solution is to have a variable area cold (or mixed) nozzle. Increasing the nozzle area at low flight speeds brings the fan working line away from surge.

An alternative solution is to fit a variable pitch fan. Scheduling the pitch of the fan blades has no impact upon the position of the fan working lines, but can be used to move the surge line upwards, to improve fan surge margin.

IP compressor map

Some turbofans have an Intermediate Pressure (IP) Compressor located between the fan and the HP compressor to increase overall pressure ratio. US civil engines tend to mount the IP compressor on the LP shaft, directly behind the fan, whereas Rolls-Royce
Rolls-Royce plc
Rolls-Royce Group plc is a global power systems company headquartered in the City of Westminster, London, United Kingdom. It is the world’s second-largest maker of aircraft engines , and also has major businesses in the marine propulsion and energy sectors. Through its defence-related activities...

 normally mount the IP compressor on a separate (i.e. IP) shaft, which is driven by an IP turbine. Either way, matching problems can arise.

Basically the IP compressor outlet corrected flow must match the entry corrected flow of the HP compressor, which is decreasing as the engine is throttled back. Now, at a certain IP compressor working line slope, the IPC outlet corrected flow remains constant. However, by adopting a shallower working line, the extra IPC pressure ratio at a given IPC entry corrected flow enables the IPC outlet corrected flow to decrease and match up with the falling HP compressor entry corrected flow. Unfortunately this can lead to a poor IPC surge margin at part flow .

Surge margin can be improved by:

a) adding variable stators to the IP compressor

and/or

b) adding a blow-off valve between the IP and HP compressors.

The former basically makes the IPC surge line shallower, swinging it away from the shallow working line, thus improving IPC surge margin.

At a given IPC pressure ratio, opening the blow-off valve forces the IP compressor entry corrected flow to increase, to a point where the IPC surge margin tends to be better. Effectively, opening the blow-off valve lowers the IPC working line. Any flow surplus to that demanded by the HP compressor passes through the blow-off valve into the bypass duct. The blow-off valve is normally only opened at throttled conditions, since it wastes energy.

External links

  • Speed-Wiz Turbocharger Compressor Map Calculation
  • SoftInWay Inc. Performance and Efficiency Maps of Centrifugal Compressor
The source of this article is wikipedia, the free encyclopedia.  The text of this article is licensed under the GFDL.
 